There are many different thermocouple configurations in addition to Temprel's standard design. Here are some specialty thermocouple designs that may help your selection:


The mechanical strength of the .125 inch diameter probe with the time response of the .062 inch. The thermocouple tip is swaged down for ¾ inch to achieve this design. This is available on all sheath materials and is commonly carried in Hastalloy (specify H for sheath material).




In some applications, the thermocouple reading can be affected by radiant energy from heat sources close to the desired gas stream reading.  This design provides a shield from these heat sources while providing for a flow path to measure the desired gas stream and protect the smaller tip.



For applications requiring continuation of the circuit ground, we off a molded on 3-prong standard plug. The grounding wire is brazed to the third copper pin to ensure continuity of the connection. Specify S3 in the connector option of the part number.


If you don't see what you are looking for here, or if you have additional questions please feel free to contact Temprel at 1-800-582-5098.