Open Wire - Temprel T52
This style is
the most basic and economical. It
consists of bare or normally insulated wire with a TIG welded measuring
junction and a form of connection to extension wire. It is available in gauge sizes 20 thru 36
with a wide choice of insulation based on the application.
Sheathed - Temprel T54
This style is
similar to the open wire type with the wire slid into a tube and the measuring
junction exposed or welded into the end of the tube. This allows the probe to be mounted in a
compression fitting and can be liquid tight.
It is still limited to the temperature of the wire insulation. Sizes are normally .125” diameter thru .250”
diameter and the tube material can be stainless steel, glass, armor or a
tightly wound spring (Boden Cable).
Sheathed MgO Filled - Temprel T21, T23, T24, T25, T26
This group
shares a common probe style of a metal sheath normally .020” thru .250”
diameter with compacted Magnesium Oxide insulation around the
thermo-elements. Most common sheath
materials are Inconel 600; 304, 310 or 316 Stainless Steel; or Hastalloy X in
single, dual or triple elements. Since
the thermo-elements are very fine and fragile, a transition to a robust
termination is required, either a quick disconnect plug (T21); or a potted
fitting (T25), a potted fitting with strain relief spring (for high vibration
applications) (T26) to flexible 20 or 24 awg lead wires. Special mounting fittings such as a pipe plug
or oil drain plug can be welded to the sheath (T23). Temperature limits are normally the upper
operating range of the thermocouple type based on calibration and diameter (see
attached chart). The thermo-elements can
also be welded into the end cap (grounded junction), exposed or electrically isolated
from the sheath (ungrounded junction).
Any of the
above types can be terminated with a molded on standard or mini plug 2 0r 3
prong or left open. Open wire styles can
include washers or any other type of brazed or adhesive backed mounting method.
Standard sheath diameters Suggested Upper Temperature Limits
.032” +.001 -.0005” 1290°F (700°C)
.040” +.001 -.0005” 1290°F (700°C)
.063” ±.001” 1690°F (920°C)
.090” ±.001” 1830°F (1000°C)
.125” +.002 -.001” 1960°F (1070°C)
.188” +.002 -.001” 2100°F (1150°C)
.250” +.003 -.001” 2100°F (1150°C)